This category has 1,584 items. Only the first 1000 records are returned.
Item # |
Dash Number (Grip) |
Grip Range |
Recommended Hole Size |
Break Off Limits |
Tensile Structural Failure (Min) |
Double Shear Min |
Material Type |
Rated Shear Strength |
Headstyle |
---|---|---|---|---|---|---|---|---|---|
FCBF2133SA( )-12LL1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 7000 lb | Double Shear Min N/A 21150 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133SA( )-12L1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 7000 lb | Double Shear Min N/A 21150 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133SA( )-12-1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 7000 lb | Double Shear Min N/A 21150 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133-12LL1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 7000 lb | Double Shear Min N/A 21150 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133-12L1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 7000 lb | Double Shear Min N/A 21150 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133-12-1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 7000 lb | Double Shear Min N/A 21150 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133SA( )-11LL1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 5000 lb | Double Shear Min N/A 17800 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133SA( )-11L1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 5000 lb | Double Shear Min N/A 17800 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133SA( )-11-1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 5000 lb | Double Shear Min N/A 17800 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133-11LL1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 5000 lb | Double Shear Min N/A 17800 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133-11L1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 5000 lb | Double Shear Min N/A 17800 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133-11-1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 5000 lb | Double Shear Min N/A 17800 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133SA( )-10LL1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 5000 lb | Double Shear Min N/A 14650 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133SA( )-10L1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 5000 lb | Double Shear Min N/A 14650 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133SA( )-10-1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 5000 lb | Double Shear Min N/A 14650 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133-10LL1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 5000 lb | Double Shear Min N/A 14650 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133-10L1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 5000 lb | Double Shear Min N/A 14650 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133-10-1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 5000 lb | Double Shear Min N/A 14650 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133SA( )-9LL1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 3000 lb | Double Shear Min N/A 12700 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133SA( )-9L1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 3000 lb | Double Shear Min N/A 12700 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133SA( )-9-1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 3000 lb | Double Shear Min N/A 12700 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133-9LL1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 3000 lb | Double Shear Min N/A 12700 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133-9L1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 3000 lb | Double Shear Min N/A 12700 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133-9-1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 3000 lb | Double Shear Min N/A 12700 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |
FCBF2133SA( )-8LL1700 | Dash Number (Grip) N/A 1700 | Grip Range N/A 1.650-1.700 in | Recommended Hole Size N/A 0.260-0.261 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 3000 lb | Double Shear Min N/A 10200 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A 130° Flush |