This category has 1,056 items. Only the first 1000 records are returned.
Item # |
Dash Number (Grip) |
Grip Range |
Recommended Hole Size |
Break Off Limits |
Tensile Structural Failure (Min) |
Double Shear Min |
Material Type |
Rated Shear Strength |
Headstyle |
---|---|---|---|---|---|---|---|---|---|
FCBF2130SA( )-7L500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.228-0.229 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 8 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-7LL500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.228-0.229 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 8 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-8-500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.260-0.261 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 10 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-8L500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.260-0.261 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 10 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-8LL500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.260-0.261 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 10 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-8-500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.260-0.261 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 10 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-8L500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.260-0.261 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 10 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-8LL500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.260-0.261 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 10 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-9-500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 13 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-9L500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 13 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-9LL500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 13 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-9-500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 13 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-9L500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 13 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-9LL500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 13 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-10-500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 15 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-10L500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 15 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-10LL500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 15 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-10-500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 15 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-10L500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 15 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-10LL500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 15 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-11-500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 18 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-11L500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 18 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-11LL500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 18 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-11-500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 18 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-11L500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 18 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-11LL500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 18 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-12-500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 7 lb | Double Shear Min N/A 21 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-12L500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 7 lb | Double Shear Min N/A 21 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-12LL500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 7 lb | Double Shear Min N/A 21 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-12-500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 7 lb | Double Shear Min N/A 21 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-12L500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 7 lb | Double Shear Min N/A 21 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-12LL500 | Dash Number (Grip) N/A 500 | Grip Range N/A 0.450-0.500 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 7 lb | Double Shear Min N/A 21 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-5-550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.165-0.166 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 1 lb | Double Shear Min N/A 4 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-5L550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.165-0.166 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 1 lb | Double Shear Min N/A 4 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-5LL550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.165-0.166 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 1 lb | Double Shear Min N/A 4 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-5-550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.165-0.166 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 1 lb | Double Shear Min N/A 4 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-5L550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.165-0.166 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 1 lb | Double Shear Min N/A 4 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-5LL550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.165-0.166 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 1 lb | Double Shear Min N/A 4 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-6-550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.199-0.200 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 6 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-6L550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.199-0.200 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 6 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-6LL550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.199-0.200 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 6 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-6-550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.199-0.200 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 6 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-6L550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.199-0.200 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 6 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-6LL550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.199-0.200 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 6 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-7-550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.228-0.229 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 8 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-7L550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.228-0.229 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 8 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-7LL550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.228-0.229 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 8 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-7-550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.228-0.229 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 8 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-7L550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.228-0.229 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 8 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-7LL550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.228-0.229 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 8 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-8-550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.260-0.261 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 10 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-8L550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.260-0.261 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 10 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-8LL550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.260-0.261 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 10 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-8-550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.260-0.261 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 10 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-8L550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.260-0.261 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 10 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-8LL550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.260-0.261 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 10 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-9-550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 13 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-9L550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 13 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-9LL550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 13 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-9-550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 13 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-9L550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 13 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-9LL550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.290-0.291 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 13 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-10-550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 15 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-10L550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 15 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-10LL550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 15 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-10-550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 15 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-10L550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 15 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-10LL550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.312-0.313 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 15 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-11-550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 18 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-11L550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 18 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-11LL550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 18 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-11-550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 18 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-11L550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 18 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-11LL550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.344-0.345 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 5 lb | Double Shear Min N/A 18 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-12-550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 7 lb | Double Shear Min N/A 21 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-12L550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 7 lb | Double Shear Min N/A 21 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-12LL550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 7 lb | Double Shear Min N/A 21 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-12-550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 7 lb | Double Shear Min N/A 21 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-12L550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 7 lb | Double Shear Min N/A 21 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-12LL550 | Dash Number (Grip) N/A 550 | Grip Range N/A 0.500-0.550 in | Recommended Hole Size N/A 0.375-0.376 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 7 lb | Double Shear Min N/A 21 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-5-600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.165-0.166 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 1 lb | Double Shear Min N/A 4 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-5L600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.165-0.166 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 1 lb | Double Shear Min N/A 4 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-5LL600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.165-0.166 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 1 lb | Double Shear Min N/A 4 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-5-600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.165-0.166 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 1 lb | Double Shear Min N/A 4 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-5L600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.165-0.166 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 1 lb | Double Shear Min N/A 4 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-5LL600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.165-0.166 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 1 lb | Double Shear Min N/A 4 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-6-600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.199-0.200 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 6 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-6L600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.199-0.200 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 6 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-6LL600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.199-0.200 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 6 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-6-600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.199-0.200 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 6 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-6L600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.199-0.200 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 6 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-6LL600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.199-0.200 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 6 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-7-600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.228-0.229 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 8 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-7L600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.228-0.229 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 8 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-7LL600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.228-0.229 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 8 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-7-600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.228-0.229 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 8 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-7L600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.228-0.229 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 8 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130SA( )-7LL600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.228-0.229 | Break Off Limits N/A 0.100-0.003 | Tensile Structural Failure (Min) N/A 2 lb | Double Shear Min N/A 8 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-8-600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.260-0.261 | Break Off Limits N/A 0.000-0.103 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 10 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |
FCBF2130-8L600 | Dash Number (Grip) N/A 600 | Grip Range N/A 0.550-0.600 in | Recommended Hole Size N/A 0.260-0.261 | Break Off Limits N/A 0.050-0.053 | Tensile Structural Failure (Min) N/A 3 lb | Double Shear Min N/A 10 lb | Material Type N/A A286 CRES | Rated Shear Strength N/A 90 KSI | Headstyle N/A Protruding |