close
close
Unit of Measure

Series

N/A SHF( )

Material Specification

N/A AMS-S-6758

Material

N/A 4130 Steel

Heat Treat

N/A 125 KSI UTS min

Finish

N/A Cadmium Plate per AMS- QQ-P-416, Type II, Class 3

Lockring Part Number

N/A RL56SA8

Nut End Type

N/A Drilled

A Nut End Thread Size

N/A 0.6250-18 UNF-3A

B Stud End Thread Size

N/A 0.7500-10

B Stud End Thread-Pitch Diameter

N/A 0.6866-0.6891 in

B Stud End Thread-Minor Diameter

N/A 0.6156-0.6314 in

D ±.015

N/A 1.000 in

E - Dia +.000 -.005

N/A 0.870 in

F ±.015

N/A 1.120 in

G ±.005

N/A 0.341 in

H ±.005

N/A 0.191 in

J ±.015

N/A 0.220 in

K Dia

N/A 0.141 in

L ±.015

N/A 1.188 in

M

N/A 0.7500-10 UNJC-3B

N -Dia +.003 -.000

N/A 0.875 in

P - Cbore Depth without O-ring

N/A 0.201 in

Q - Cbore Depth with O-ring

N/A 0.274 in

Tap Drill Size

N/A 0.656 in

O-Ring Size

N/A AS568-115

Counterbore Tool Part Number

N/A RC56-656

Basic Tap Size

N/A 0.7500-10 UNC

Drive Wrench Number

N/A R1111W

Lockring Drive Tool Part Number

N/A S161D16

Removal Tool Part Number

N/A BT8063

Notes

N/A
  • <1>The stud end thread has a special pitch dia and minor dia which installs into a MIL-S-8879 class 3B. FED-STD-H28/2 Class 3B, or national Class 3 tapped hole.
  • <3>Maximum 2 incomplete threads
  • Mating Lockring is not included with stud. It must be ordered separtely
  • 4130 Steel and A286 Cres indicate stabdard materials
  • For Titanium with anodic treatment per AMS 2488, Type 2, add suffix EO301 to stud part number.
  • Taps are not supplied by Howmet
  • "B" diameter and Minor diameter of thread to be concentric within .003 film
  • Thread as shown per AS8879 is prefered. Alternate thread per FED-STD-h28/2 Class-3B or national Class 3 is applicable when specified by design activity.
  • Without O-ring: Use to effect fluid seal for pressures up to 150 psi. Install part until top serrated flange is .010 to .020 below surface.
  • Without O-ring: Use for dust and foreign matter exclusion. Install part until flange is seated in counterbore. Don't use excessive wrench torque.
  • O-ring must be specified separately and shall be selected based on system fluid and temperature and are not supplied by Howmet. O-ring sizes per AS 568. With proper installation and proper choice of O-ring, fluid seal up to 150 psi will be effected.
  • Drive lockring from .005 to .010 below material surface.