Print Back
THREAD: AS8879 Class-3A
  1. MATERIALS:
    • Fitting: 6Al-4V Titanium per AMS4965, 130 KSI UTS min.
    • Lockring: A286 Cres per AMS5731 or AMS5737, 34-40 HRC.
  2. FINISH:
    • Fitting: anodic treatment per AMS2488, type 2.
    • Lockring: passivate per AMS2700, type 2 and PTFE coating (color: white).
Unit of Measure

Specifications

SAE Part Number

N/A AS5865-16-12

Tube OD

N/A 0.750 Inch

A Thread AS8879 Class-3A

N/A 1.0625-18 UNJEF Inch

B Thread AS8879 Class-3A

N/A 1.1250-18 UNJEF Inch

C Dia. (± .005)

N/A 1.456 Inch

D Diameter

N/A 0.804-0.851 Inch

E Dia. (+.005/-.002)

N/A 1.000 Inch

F Dia. Min

N/A 1.154 Inch

G Dia.

N/A 1.251 Inch

H( ± .007)

N/A 0.220 Inch

J (+.010/-.005)

N/A 0.157 Inch

K( ± .005)

N/A 1.159 Inch

M No. of Teeth

N/A 36

O-Ring Size

N/A AS568-120

Weight

N/A 0.1652 lb/ea

HFS port PS10035

N/A PS10035-16

SAE Port AS5551

N/A AS5551-16

P Max

N/A 0.140 Inch

R( ± .0175)

N/A 0.979 Inch

Porting Tool No.

N/A RPT16

Chip Removal Tool Number

N/A RF16CRP

Broach Tool Non-Impact Type Number

N/A RFOPB5016HDB

O-Ring Installation Tool Number

N/A ORT1125

Drive Wrench Number

N/A RF6916W

Lockring Drive Tool Part Number

N/A RF9816DEK

Lockring Removal Tool Number

N/A RF16LPDE

Engineering information

N/A

  1. Adapters are primarily designed for use in 5080 psi hydraulic working pressure systems (ref: SAE Spec AS5000) compatible with titanium.
  2. These parts provide semi-permanent male adapter Installations in valve and cylinder bodies, Manifolds etc…
  3. Serrated lockring prevents rotation when mating lines are attached or removed.

Installation information

N/A

  1. Adapters to be installed and removed per SAE AS5551.
  2. “P” and “R” stand-off dimensions are for design purposes only. Do not use as installation data.
  3. O-rings must be specified separately and shall be selected based on system fluid and temperature and are not supplied by HFS.
  4. Coupling nuts used with this adapter must have threads in accordance with AS8879.

Notes

N/A Unless otherwise specified

  1. Lockring retained on adapter by controlled interference fit.
  2. Sealing surface: no visible defects. To be protected for shipment. Take care in handling.
  3. Adapters are used in conjunction with an O-ring. O-ring size per AS568 (compound NAS1613).
  4. Identification:
      a. Mark at location shown per AS478, method 2 or 15, manufacturer’s name, trademark or cage code.
      b. Bag and tag per AS478, method 35D. Manufacturer’s name, trademark or cage code, customer part number if applicable, HFS part number and lot number.
  5. All machined surfaces shall be smooth to 125 microinches Ra, serration 250 microinches Ra and sealing surfaces 63 microinches Ra per ASME B46.1.
  6. Protective individual packaging mandatory.
  7. Procurement specification: SAE AS5000 except as specified on this standard.