close
close
THREAD: ISO 5855-3 (MA1370) -4g6g
  1. MATERIALS:
    • Fitting: 6AI-4V titanium per AMS4928, AMS4965 or AMS4967 annealed, 900 MPa UTS MIN.
    • Lockring: A286 cres per AMS5731 or AMS5734, 34-40 HRC.
  2. FINISH:
    • Fitting: Dry film lubricant per AS5272, Type I, on all surfaces except none in flow hole.
    • Lockring: Passivate per AMS2700, Type 2.
Unit of Measure

Tube OD (REF)

N/A 4.000

A Thread
ISO 5855-3 (MA1370)
-4g6g

N/A MJ8x1

B Thread
ISO 5855-3 (MA1370)
-4h6h

N/A MJ5x0.8

C (± .09)

N/A 10.150

D

N/A 3.00-3.06

E (+.20/-0)

N/A 2.000

F (+0.15/-0.05)

N/A 3.700

G (REF)

N/A 8.050

H (MIN)

N/A 6.250

K (± .20)

N/A 14.950

L (+.50/-0)

N/A 7.100

M (+.15/-.10)

N/A 2.450

N (± .40)

N/A 10.000

P (± .20)

N/A 4.900

O-Ring Size (REF)

N/A A0035

Adapter weight kg/100 pcs approx

N/A 0.350

Port Rosan No.

N/A PS10047-070

R (± .50)

N/A 10.750

S (MAX)

N/A 3.100

Porting Tool No.

N/A RPTM070

Basic Broach Tool Impact Type

N/A RFMOPB070

O-Ring Installation Tool Number

N/A ORTM0508

Combination Wrench and Drive Tool

N/A RFM070-0810DW

Lockring Removal Tool Number

N/A RFM070LPDE

N/A ENGINEERING INFORMATION:
a. THESE PARTS ARE PRIMARILY DESIGNED FOR USE IN 28 MPa HYDRAULIC WORKING PRESSURE SYSTEMS, 235°C MAX TEMPERATURE AND COMPATIBLE WITH TITANIUM.
b. THESE PARTS PROVIDE SEMI-PERMANENT MALE ADAPTER INSTALLATIONS IN VALVE AND CYLINDER BODIES, MANIFOLDS ETC. WITH 115 MPa SHEAR STRENGTH MINIMUM.
c. SERRATED LOCKRING PREVENTS ROTATION WHEN MATING LINES ARE ATTACHED OR REMOVED.

N/A INSTALLATION INFORMATION:
d. ADAPTERS TO BE INSTALLED AND REMOVED PER HFS TECHNICAL SALES BULLETIN TSB80-0305 OR AECMA EN2608 OR SAE MA2114.
e. "R" AND "S" STAND-OFF DIMENSIONS ARE FOR DESIGN PURPOSES ONLY. DO NOT USE AS INSTALLATION DATA.
f. THIS DIMENSION MEETS THE MINIMUM REQUIREMENTS OF AECMA STANDARD EN2604, EXCEPT -04 PER MBB STANDARD NO. TKF-4500F-01-02.
g. O-RINGS MUST BE SPECIFIED SEPARATELY AND SHALL BE SELECTED BASED ON SYSTEM FLUID AND TEMPERATURE AND ARE NOT SUPPLIED BY HFS.

N/A NOTES: UNLESS OTHERWISE SPECIFIED
2. LOCKRING RETAINED ON ADAPTER BY CONTROLLED INTERFERENCE FIT. ONE TOOTH REMOVED FROM THE LOCKRING EXTERNAL SERRATION FOR METRIC IDENTIFICATION PURPOSES.
3. SEALING SURFACE: NO VISIBLE DEFECTS. TO BE PROTECTED FOR SHIPMENT. TAKE CARE IN HANDLING.
4. THIS PART IS USED IN CONJUNCTION WITH AN O-RING. O-RING SIZE PER MA2010 (IS03601/I SERIES A).
5. ALL INTERIOR PACKAGES SHALL BE MARKED WITH EN3566-( ) IDENTIFICATION NUMBER, EXCEPT FOR SIZE -04, AND SHALL ALSO BE DURABLY MARKED WITH THE COMPLETE HFS PART NUMBER PER EN2424, STYLE G (AS478, METHOD 35D).
6. SURFACE ROUGHNESS: MACHINED SURFACES SHALL BE SMOOTH TO 3.2 MICROMETER Ra, EXCEPT SERRATION 6.3 MICROMETER Ra AND SEALING SURFACES 1.6 MICROMETER Ra PER ASME B46.1.