close
close
ACCU-LOK® II blind fastener for interference fit application in metallic structure 100° flush tension head A-286 stainless (95 KSI Fau CRES).
Unit of Measure

Dash Number (Grip)

N/A 400

Grip Range - Min. Grip

N/A 0.350 in

Grip Range - Max. Grip

N/A 0.400 in

Grip Range

N/A 0.350-0.400 in

A Theo. Dia

N/A 0.538 in

B Dia Min

N/A 0.494 in

D Dia

N/A 0.292 in

E Dia Max

N/A 0.290 in

F Wrench Flats

N/A 0.152 in

G Ref.

N/A 0.065 in

H Ref.

N/A 0.104 in

L Ref.

N/A 0.815 in

R Rad Max

N/A 0.030 in

S Max

N/A 0.020 in

T Across Hex. Ref

N/A 0.500 in

Minimum available grip length

N/A -200

Recommended Hole Size

N/A 0.290-0.291

J Dia Min

N/A 0.450 in

K Max

N/A 0.500 in

Break off Limits <5>

N/A 0.100-0.003

Tensile Structural Failure (Min) <7>

N/A 3000 lb

Double Shear Min

N/A 12700 lb

Locking Torque Min

N/A 3.000 lb-in0.339 N-m

V Gage Prot.

N/A 0.045 in

W Gage Dia

N/A 0.432 in

Material and Heat Treat

N/A Nut: A-286 stainless steel per chemical requirements of AMS 5732, heat treated as required for performance.
Corebolt: Inconel 718 per AMS 5662, heat treated to 125 ksi Fsu
Sleeve: 304 stainless steel per AMS 5639, heat treated as required for performance.
Insert: Acetal per ASTM D4181
DryvcapTM: Mild steel.

Finish

N/A Nut, Sleeve & Corebolt: Passivate per AMS-QQ-P-35. KAL-GARD ANN-RO #1013 conversion coating optional.
Insert: None
DryvcapTM: Corrosion resistant coating, color black.

Lubricants

N/A The following lubricants may be applied to any or all components in any combination as required for performance unless otherwise specified: Dry film lube per AS5272, Type I, everlube #812, paraffin wax, or cetyl alcohol per MIL-L-87132.

Applicable Specification

N/A Procurement specification: FCBF200
Special lube and finish: FCBF202

Material Type

N/A A286 CRES

Rated Shear Strength

N/A 90 KSI

Headstyle

N/A 100° Flush

Notes

N/A 2.Locking feature consists of three (3) indentations located 120° apart on the periphery of the nut component and approximately .040" above intersection of the nut nose angle and O.D.
<3>Alternate head marking: "VS" and "O"
4.Composite blind fasteners with selected combinations of the above lubrications and finishes are specially coded and may be substituted for equivalent non-coded parts at manufacrure´s option. Contact Fairchild Engineering.
<5>An "L" in place of the dash (-) between the diameter dash number and the grip dash number designates midified break-off limits of +.053/-.050. (e.g. FCBF2132( )-6L200). An "LL" designates modified break-off limits of +.003/-.100 "e.g. FCBF2132( )-6LL200".
<6>Distortion shall not prevent insertion of the fastener into a ring gauge of length equal to one diameter and hole diameter equal to a minimum recommended hole. Insertion force shall not exceed 5.0 lbs.
<7> Proposed minimum tensile structural failure values.
8. These parts are intended for applications requiring up to a .002" diametrical interference fit between fastener shank and structure hole.